Baldor BALDOR GENERATOR Portable Generator User Manual


 
Sectional
No./mm
A
mm'
wlre element current area
Gauge
No./
Allowable
0.75
17
2.0
5010.18
12
1.25
3010.18
7
7010.32
35
5.5
45
10.32
23 3.5
37
10.26
I
Voltage
Table
7-2
Voltage drop indicates as V
=
100
XRXIXl
R
means resistance
(
52
/lo0
m)
on
the above table.
I
means electric current through
the
wire
(A).
4!
means the length of the wire
(m).
The length
of
wire indicates round length, it means twice the length from generator to electrical tools.
7-2 DC OUTPUT
NOTE
:
Do not use DC and AC output simultaneously.
Due
to
a
characteristic
of
the condenser voltage regulation, simultaneous
use
of
DC and
AC output creates voltage drop in DG output resulting in incapability
for
charging batteries.
When the generator
is
employed
to
charge batteries, attentions should be paid to the specific gravity
of
electrolyte in the battery.
7-2-1 SPECIFIC
GRAVITY
OF
BATTERY ELECTROLYTE
The specific gravity
of
electrolyte varies by temperature
;
so
it
must be converted to the one at
20°C.
S20
=
St
+
0.0007
(t-20)
where
S20
:
The specific gravity at
20°C
St
:
Measured value
t
:
Temperature at the time
of
measurement (Electrolyte)
-
18
-