Ariens 936305-313 Lawn Mower User Manual


 
11 - 49
Contact Resistance Is 0.1-0.3 Ohms When Correct.
Normally Open Contacts Manually Activated. Contact Resistance Is 0.1-0.3 Ohms When Correct.
2 Sets Of Contacts, One Normally Open, One Normally Closed. Contact Resistance Is 0.1-0.3 Ohms When
Correct
Normally Open Contacts Manually Activated. Contact Resistance Is 0.1-0.3 Ohms When Correct.
Pins 85-86 Coil Resistance 87-100 Ohms. Pins 30-87 Normally Open. Pins 30-87a Normally Closed. Contact
Resistance Is 0.1-0.3 When Correct.
Key Switch Off Run Start
B 11:50-13:00 11.50-13.00 Vdc 11.50-13.00 Vdc
A 11.50-13.00 Vdc 11.50-13.00 Vdc
S-1 11.50-13.00 Vdc
S-2 11.50-13.00 Vdc 11.50-13.00 Vdc
Seat Switch Off Run Start
Pink 11.50-13.00 Vdc 11.50-13.00 Vdc
Black Connected To Ground
PTO Switch Off Run Start
Yellow/red (2) 11.50-13.00 Vdc 11.50-13.00 Vdc
Purple/white (2) Connected To PTO Clutch And Light
Purple 11.50-13.00 Vdc 11.50-13.00 Vdc
Brown/yellow 11.50-13.00 Vdc 11.50-13.00 Vdc
Brake Switch Off Run Start
Brown/yellow 11.50-13.00 Vdc 11.50-13.00 Vdc
Red/violet (3) 11.50-13.00 Vdc 11.50-13.00 Vdc
Relay #1 Off Run Start
Pink
85
11.50-13.00 Vdc 11.50-13.00 Vdc
Purple 86 11.50-13.00 Vdc 11.50-13.00 Vdc
Yellow/red 87 11.50-13.00 Vdc 11.50-13.00 Vdc
87a
Not Used Not Used
Purple (3) 30 11.50-13.00 Vdc 11.50-13.00 Vdc