Agilent Technologies 5988-7401EN Sprinkler User Manual


 
Combining Parameters for Signal Generation Using the Agilent 81133A/81134A Pulse Generator
Agilent 81133A/81134A Pulse Generator User’s Guide, January 2005 73
Clock Sources
The selected clock source defines the time base from which all other
timing parameters are derived. You can select between:
•Internal
The clock is derived from the internal YIG oscillator.
•External
external 10 MHz reference (clock source); clock sources:external 10
MHz reference
Enable the external clock input (Clock In) to accept an external
clock signal that forms the time base. The frequency is measured
once by selecting the Measure function from the user interface or as
a remote SCPI command (
:MEASure:FREQuency?
).
This value is then used to calculate frequency-dependent values,
like the pulse width or the phase (available at the Channel page).
For more information about the Measure function, please refer to
the Online Help.
External 10 MHz Reference
ext. direct (clock source); clock sources:ext. direct
Enables the external clock input (Clock In) to apply a 10 MHz
reference clock. This clock is used as a reference for all timing
parameters.
Int. Direct/Ext. Direct
The direct modes allow changes of frequency without dropouts in
the range of 1:2. They are used for applications (precise clock
source) where dropouts would make a measurement impossible, for
example, PLL frequency sweeps and microprocessor clock sweeps.
Measure Function
Clock Source