3M 2600 Telescope User Manual


 
9
6.0 Cleaver Operation
6.01 The Alcoa Fujikura Model CT-03, CT-04, CT-04B, or CT-07, is
required for the cleaving process.
Note: Sumitomo Model FC-4 Cleaver may also be used, along
with the 2651-A Fiber Viewer.
5.03 Lay the stripped ribbon between the guide forks. The ribbon
should be positioned so that 1" to 2" (25 mm to 51 mm) of
unstripped ribbon extends beyond the end of the holder.
5.04 Place the cover over the ribbon and snap into place.
6.02 If present, the guide plate must be removed so that the cleaver
spacer gauge assembly can be installed. Remove the screws
that secure the guide plate. Remove the guide plate.
6.03 Install the cleaver spacer gauge in the slot. The spacer should be
snug against the wall near the rubber pad.