10.05 Turn the splice over and verify that the wedge has been fully
pushed against the splice body.
10.06 If the wedge is not against the splice body, move the actuation
lever to the right, place the splice back into the actuator tool and
squeeze the actuation lever again.
10.07 Remove the ribbon holders from the actuator tool.
10.03 Remove the cover of each ribbon holder by squeezing the center
tabs and lifting the outer tabs.
10.04 Gently lift the splice and ribbons out of the actuator tool.
11.0 Multi-Fiber Stripper Cleaning and Maintenance
11.01 Tube Guide
a. The stripper tube guide should be cleaned periodically to
ensure good performance. Remove the tube guide by
unlatching the tube lock with the white pushout tool. Pull the
tube guide out of the pivot housing.
b. Clean the inside of the tube guide with compressed air. A
length of unstripped ribbon may also be used for cleaning if
compressed air is not available. Also clean around the
outside tip of the tube guide.
Clean