6.09 Depress the cleaving lever 3 firmly.
6.10 While holding the cleaving lever down, remove the cleaved fiber
stubs, and dispose of per company practice.
7.0 Visual Inspection of the Cleave
7.01 Install the fiber viewer on the cleaver and rotate the viewer barrel
to focus. Observe the cleaved ends of the fiber. If defects are
observed, repeat steps 4.05 through 6.11.
Note: For the best viewing results, allow ample light to enter
from the top and left side. In dark surroundings use the
penlight supplied.
7.02 Properly cleaved fibers.
6.11 Open the cleaving lever and clamping lid.