3M 2600 Telescope User Manual


 
14
10.0 Splice Actuation
10.01 Actuate the splice by squeezing the actuation lever slowly until it
stops.
10.02 Close both splice covers.
Note: Some protective gel may be visible after closing covers.
9.02 Look at the amount of bare glass where each ribbon enters the
splice. The amount of bare glass should be about the same on
each side.
9.03 If necessary, center the ribbons by selecting the pre-load lever
that is closest to the shorter length of bare glass. Slowly slide the
lever back (away from you) until the holders move and the ribbons
appear centered.
9.04 Return the lever to its forward position. If the ribbon was adjusted
too far, re-adjust using the other lever.
Note: Make sure both pre-load levers are all the way forward
(toward you) when done.
NOT CENTERED
CENTERED