Xantrex Technology 200 Portable Generator User Manual


 
Troubleshooting Reference
36
Measured AC
output voltage
is too low.
Use of an
average-reading, AC
voltmeter to read output
voltage.
XPower Powerpack
battery is almost fully
discharged.
The modified sinewave (MSW)
output of the XPower Powerpack
requires a true RMS reading
meter, such as the Fluke 87
series, for accurate
measurement.
Press Battery Level button to
verify battery status and recharge
the XPower Powerpack as
necessary. Battery Level LEDs
are only accurate when the
PowerBox has been
disconnected from all appliances
and all charging sources for
fifteen minutes.
The light does
not turn on.
Light bulb has burnt out. Remove lens cover and replace
bulb with one of the same type
and rating.
Battery Status
LED is OFF
when AC
Charger is
connected
No AC power at the AC
wall outlet.
AC Charger is faulty.
Ensure power is available at the
AC wall outlet.
Replace the AC Charger.
Battery Status
LED is red and
Battery Level
LEDs show
the battery is
full when the
Battery Level
button is
triggered.
Battery Level lights are
only accurate when the
XPower Powerpack has
been disconnected from
all appliances and all
charging sources for 15
minutes.
Unplug the charging sources and
any appliances and let the
XPower Powerpack rest for 15
minutes to obtain an accurate
reading.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution