Xantrex Technology 200 Portable Generator User Manual


 
Troubleshooting Reference
35
AC appliance
will not
operate;
audible alarm
is sounding.
Battery has discharged to
10.5 V.
XPower Powerpack has
overheated due to poor
ventilation or excessively
warm environmental
conditions.
Turn OFF the AC Power On/Off
Switch and recharge the XPower
Powerpack.
Turn the AC Power On/Off
Switch OFF and allow the
XPower Powerpack to cool for
15 minutes or more. Clear
blocked opening or remove
objects covering the unit, then
restart the XPower Powerpack
and move it to a cooler
environment.
Run time is
less than
expected.
XPower Powerpack
battery is not fully
charged.
AC appliance power
consumption is higher
than expected.
Environmental
temperature is less than
0°C (32°F) or more than
40°C (104°F)
Recharge using the AC Charger,
until Battery Status LED is
green.
Check AC appliance power or
wattage rating (or current draw
for 12 V DC appliances) and
compare with Table 3-1 on
page 13 and Table 3-2 on
page 16.
Operate within correct
temperature range.
Table 5-1
Troubleshooting reference
Problem Possible Cause Solution
XPower_PP_200_Plus.book Page 35 Monday, October 23, 2006 2:57 PM