Appendix A: Specifications
20
CFG280 User Manual
Table 4: General Specifications
Characteristic
Measurement
Line Voltage Range Selectable ranges at 50 Hz to 60 Hz
90 VAC to 110 VAC
108 VAC to 132 VAC
198 VAC to 242 VAC
216 VAC to 250 VAC
Operating Temperature
+0_ĂC to +40_ĂC, 80% relative humidity
Nonoperating Temperature
–10_ĂC to +70_ĂC, 70% relative humidity
Table 5: Certifications and Compliances
EC Declaration of
Conformity – EMC
Meets intent of Directive 89/336/EEC for Electromagnetic
Compatibility. Compliance was demonstrated to the following
specifications as listed in the Official Journal of the European
Communities:
EN 55011 Class A Radiated and Conducted Emissions
EN 50081-1 Emissions:
EN 60555-2 AC Power Line Harmonic Emissions
EN 50082-1 Immunity:
IEC 801-2 Electrostatic Discharge Immunity
IEC 801-3 RF Electromagnetic Field Immunity
IEC 801-4 Electrical Fast Transient/Burst Immunity
IEC 801-5 Power Line Surge Immunity
EC Declaration of
Conformity – Low
Voltage
Compliance was demonstrated to the following specification as
listed in the Official Journal of the European Communities:
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC.
HD401 S1 Safety Requirements for Electronic
Measuring Aparatus.