English
Place the stop switch s in the "STOP" position.
Remove accumulation of grease, oil, dirt and debris from
exterior of unit.
Perform all periodic lubrication and services that are
required.
Tighten all screws and nuts.
Drain the fuel tank completely and pull the recoil starter
handle several times to remove fuel from the carburetor.
2.
3.
4.
5.
6.
Remove the spark plug and pour 7cc (1/4 oz.) of fresh,
clean Shindaiwa 2-stroke engine oil into the cylinder
through the spark plug hole.
7.
storaGe
WARNING
During operation the mufer or catalytic mufer and surrounding cover becomes hot. Always keep exhaust area clear of
ammable debris during transportation or when storing, otherwise serious property damage or personal injury may result.
Long Term Storage (Over 30 Days)
Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage mainte-
nance which includes the following:
Store unit in a dry, dust free place, out of the reach of children.
WARNING
Do not store where fuel fumes may accumulate or reach an open ame or spark.
1.
Place a clean cloth over the spark plug hole.
Pull the recoil starter handle 2-3 times to distribute
the oil inside the engine.
Observe the piston location through the spark plug
hole. Pull the recoil handle slowly until the piston
reaches the top of its travel and leave it there.
A.
B.
C.
Install the spark plug (do not connect ignition cable).
Remove blower pipe assembly from unit.
8.