- 26 -
!
Caution
:Burns
Do not open the radiator cap while operating this equipment or immediately after stopping
the equipment, to avoid sustaining burns from hot vapor.
Do not touch the engine and muffler during operation and immediately after stopping
the equipment, for the temperature can reach extremely high.
Check the radiator and coolant reservoir tank for water and add water in case of shortage.
8.2.1 Checking Radiator / Adding water
Remove the radiator cap
Fill up the radiator up to the top
Install the cap back and tighten
<Caution>
With respect to DG150MI, check and add water,
after unscrewing the bolt holding the radiator cap.
8.2.2 Checking Coolant reservoir tank / Adding coolant
Check to see if the coolant level is between MIN and MAX line
Fill up to the MAX line, if the coolant level is low
<Caution>
Use soft water, such as tap water
If the outside temperature is near freezing,
use Long Life Coolant (LLC)
(30% mixture LLC is used, when shipped from factory)
Use same type of coolant with identical mixture ratio
for the reservoir tank
Mixture ratio of the coolant should be between 30
to 45%, depending on the outside temperature
Replace LLC every 2 years or 400 hours
Mixture ratio (for reference only)
Ambient
temperature
(Celsius)
-15
-20
-30
Mixture ratio 30% 35% 45%