ASSEMBLY INSTRUCTIONS
9
Fig. 8
Fig. 7
Clip
Support Fitting
3. Snap the clip on to the support fitting (Fig. 7).
4. While standing in the operating position adjust length
to fit the operator’s size. Pull tab to lengthen, pull
strap to shorten (Fig 8).
Clip
INSTALLING THE HARNESS
WARNING: To avoid serious personal injury,
never attempt to start the unit when standing
and the unit clipped to the shoulder strap.
Always follow the starting procedures as
described in the Operation section.
1. Push the strap through the center of the buckle.
2. Pull the strap over the cross bar and down through
the slot in the buckle (Fig. 6).
Fig. 6
Removing
1. Press the latching tabs on both sides of the vacuum
bag tube and pull the vacuum bag down from the
unit (Fig. 5).
2. Detach the vacuum bag from the vacuum bag hook.
Fig. 5
Latching Tabs
Vacuum Bag
Vacuum Bag Hook
Debris Exhaust Tube
Vacuum Bag Tube
Zipper
Fig. 4
Fig. 3
Latching Tabs
ATTACHING AND REMOVING THE VACUUM BAG
Attaching
1. Attach the vacuum bag to the vacuum bag hook on
the blower/vacuum tube (Fig. 3)
2. Slide the vacuum bag tube over the debris exhaust
tube on the housing. Push the tube until the latching
tabs on both sides click into place, securing the bag
on the unit (Fig. 4).
PRESS IN
PRESS IN