Quadra-Fire SAPPH-D-CSB Patio Heater User Manual


 
Page 12
January 28, 2008
Quadra-Fire · Sapphire · 250-7233F
Female Locking Lugs
Male Locking Lugs
Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.
F. Horizontal Termination
Figure 5.4
Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall
thickness in minimum clearances when figuring venting
lengths for your installation needs.
Note: Female ends of direct vent pipe/elbows are designed
to slide straight onto the male ends of adjacent pipes by
orienting the pipe indentations so they match and slide into
the entry slots on the male ends, see Figure 5.4. Push
the pipe sections completely together, then twist-lock one
section clockwise approximately one-quarter turn, until the
two sections are fully locked. The female locking lugs may
not be visible from the outside. They may be located by
examining the inside of the female ends.
Figure 5.3
90 DEGREE
ELBOW
PIPE LENGTH
PIPE LENGTH
WALL
THIMBLE
COVER
Temination Cap
(Recommended
for optimum
performance)
WALL
THIMBLE
On horizontal terminations use Hearth & Home Technologies
Part #HHW2, or like components.
This is the only venting configuration that requires the
use of the rear vent derating orifice that comes with the
rear vent kit. NOTE: A Snorkel Kit is required.
Rear Installations for Use with Rear
Vent Kit
Type B -
Up & Out Installations for Top Vent
Configurations
Type A -
WALL THIMBLE
COVER
PIPE LENGTH
WALL STRAP
14 in. (356mm) Wide
C
21 in.
(533mm)
WALL THIMBLE
SNORKLE KIT
15-5/8 in.
(397mm)
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
Maintain all clearances to combustibles.
Do NOT allow vent to sag below connection
point to appliance.
Maintain speci ed slope (if required).
WARNING
Improper support may allow vent to sag or separate.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.