3
IntelliChlor User’s Guide
Power Center
The Power Center converts AC electrical current to a low voltage DC current which is required by the cell to
perform the electrolysis. The power supply is connected with the pool circulation pump electrical source so
that the electrolytic cell only operates when the pool pump is on. The enclosure can be mounted vertically on
the wall up to 15 feet away from the cell controller. The Power Center contains the transformer, fuse,
connector to the cell and the 110 VAC and 220 VAC wiring configuration with the 36 VDC output cable to the
cell controller. A fuse holder is mounted on the bottom of this enclosure for additional protection. There are no
other controls or lights on the unit. For more information about the Power Center, see the “IntelliChor Power
Center Installation Guide,” (P/N 520590).
System Diagram
The following diagram shows the IntelliChlor system functionality. It is recommended to install a 2” check
valve between the input side of the IntelliChlor cell and the main heater output pipe.
Power Center (Model PC 100)
Pool pump and
Power Center MUST
be wired to switch
on and switch off
together
Power Center
Pentair 2” Check Valve
(recommended)
(P/N 263042)