5
IntelliChlor User’s Guide
Section 1
IntelliChlor Control Panel
This section describes the IntelliChlor control panel status LEDs and the More, Less and Boost/On/Off control
buttons.
Salt Level Status LEDs
The salt level is checked daily and is displayed on this section of the unit.
• Green: Good salt. The water salt level is above 2900 ppm, the
cell will produce chlorine. Flash green: Salt is above 4000 ppm.
Chlorine is being produced but the pool water may be corrosive to
other pool equipment. Water needs to be drained and refilled one
foot at a time until the salt level is lowered.
• Yellow: Low salt. The water salt level is between 2500 ppm and
2900 ppm, salt should be added to the pool. The cell will continue
to produce chlorine, but will be at a reduced level.
• Red: Very low salt. The water salt level has fallen below 2500
parts per million (ppm). The cell will not produce chlorine until
additional salt is added.
Note: When connected to an IntelliTouch system the Less and
More buttons are disabled and IntelliChlor Sanitizer Output is
controlled from the IntelliTouch Indoor Control Panel.
Status LEDs
Pwr: Shows the condition of the system:
• Red: An error is occurring in the system. Service is needed.
• Green: The system is operational and ready.
Cell: This light is on if the cell is producing chlorine.
• Red: Water temperature is below 59° F, cell is shut off.
• Green (flashing): Cell is bad, may have calcium buildup, time to
clean.
• Green: Cell is good and producing chlorine
• Blank: Cell is off and not producing chlorine. It may be in an
off-period of the sanitizing cycle and will return on shortly.
Life: The cell is designed to operate for approximately 10,000 hours
before replacement is needed or approximately five years of average use.
• Green (flash): The cell is over 10,000 hours of life, replace soon.
• Green: The cell is under 10,000 hours of life, good.
Flow: This light indicates water is flowing through the cell to produce
chlorine.
• Red: Insufficient water flow through the cell, no chlorine will be
produced.
• Green: Sufficient water to produce chlorine.
Conforms to
UL STD 1081
3077230
US