Pentair IC20, IC40 Portable Generator User Manual


 
6
IntelliChlor User’s Guide
Operator Control Panel (continued)
Sanitizer Output LED Indicators
The five LED indicators display as a bar graph to show in 20% increments, the amount of time the chlorine is
produced per hour. In BOOST mode, these LEDs scroll in a pattern.
Note: If no LEDs are lit
0% No LEDs on indicate no chlorine produced - IntelliChlor is off
20% Produces chlorine 20% of the hour, 12 minutes on, 48 minutes off
40% Produces chlorine 40% of the hour, 24 minutes on, 36 minutes off
60% Produces chlorine 60% of the hour, 36 minutes on, 24 minutes off
80% Produces chlorine 80% of the hour, 48 minutes on, 12 minutes off
100% Produces chlorine 100% of the hour, 59 minutes on, 1 minute off
Control Buttons
The More and Less buttons control the sanitizing cycle as displayed by the sanitizer output display bar graph.
Slide the panel cover up to access the More, Less and Boost On/Off buttons.
More Increases the time the cell produces chlorine, in 20% increments. Press and hold
this button to access the “System Status” mode to display the current usage
hours. For more information, refer to “Cell Usage Hours Meter,” on page 10.
Example: The Sanitizer Output display is showing 20%. Pressing the
More button will turn off the 20% light and turn on the 40% light. The unit
will now produce chlorine 40% of the hour.
Less Decreases the time the cell produces chlorine, in 20% increments.
Example: The Sanitizer Output display is showing 40%. Pressing the
Less button will turn off the 40% light and turn on the 20% light. The unit
will now produce chlorine 20% of the hour.
Boost On/Off Press and hold both the More and Less buttons activates Boost mode. Boost
mode sets the sanitizer output to run 100% for 24 hours straight. If the time clock
switches off the pump cycle, then switches power back on the next day, Boost
mode will continue until 24 hours has elapsed or Boost mode is canceled by the
user. The Sanitizer Output display will show a pattern LED display to indicate
Boost mode. To exit Boost mode, press and hold both the More and Less buttons.
Self Cleaning (reverse)
The unit has a self-cleaning feature that reduces scale build-up on the cell blades. The self-cleaning cycle
tends to reduce cell life, so less often is better, however, it is important to minimize the scale build-up on the
blades. The cycle can be every 2, 4, 6, 8, or 10 hours. It is factory set to two hours for the first 30 days of
operation, and then four hours thereafter. To change the self-cleaning cycle, press and hold the Less button
for three seconds. The sanitizer output display will now correspond to the self-clean cycle. Pressing More or
Less button will change this setting.
Example: The self-clean cycle is set to four hours and needs to be two hours. Press and hold the Less button
for three seconds. The sanitizer output will blank, then light up the 40% LED light only, indicating four hours.
If no button is pressed for five seconds, the display will return to the sanitizer output display. Pressing the Less
button within five seconds will now light the 20% LED light, indicating it is now at two hour self-clean cycle.
Wait five seconds and this mode will end, returning to the sanitizer output display.