Pentair IC20, IC40 Portable Generator User Manual


 
13
IntelliChlor User’s Guide
Optimum Pool Water Conditions
In accordance with the Association of Pool and Spa Professionals (APSP) standards, it is recommended that
the following water balance conditions be maintained on an on going basis to protect the pool finish and
equipment and ensure the pleasing appearance of the water. IntelliChlor is warranted to operate properly only
if these conditions are met.
Free Chlorine: 2.0 - 3.0 PPM. Above 3.0 PPM may cause corrosion of pool metals
Combined Chlorine (Chloramines): None (Super Chlorinate to remove all Chloramines)
PH: 7.2 - 7.8 (USE MURIATIC ACID to lower pH and Soda Ash to raise pH.)
Chlorine Stabilizer (Cyanuric Acid): 50 - 75 PPM
Total Alkalinity: 80 - 120 PPM
Calcium Hardness: 150 - 400 PPM
Metals (Copper, Iron, Manganese): None
Nitrates: None