Pentair IC20, IC40 Portable Generator User Manual


 
21
IntelliChlor User’s Guide
Connecting the Cell Assembly to the IntelliTouch System
To operate IntelliChlor via the IntelliTouch Indoor Control Panel, connect a 4-wire cable from the IntelliChlor
Power Center to the Personality board located in the IntelliTouch Load Center. An alternate connection can be
made by splicing the Indoor Control Panel connection wire connected to the Personality board.
Note: For IntelliChlor operating instructions using the IntelliTouch system, see the “IntelliTouch User’s
Guide” (P/N 520102).
To connect IntelliChlor to the IntelliTouch Load Center:
1. Remove the cover screw securing the Power Center cover. Remove the cover.
2. Run a UL approved four conductor cable (22 AWG) from the IntelliChlor Power Center to the Load
Center. The preferred wire color scheme is red, yellow, green, and black.
3. Remove the cover screw securing the Power Center cover. Remove the cover.
4. Remove one of the knockouts from the underside of the Power Center.
5. Route the four conductor cable up through the lower hole.
6. Strip back the cable conductors ¼ in. Insert the wires into the screw terminals (provided in the kit).
Secure the wires with the screws. Make sure to match the color coding of the wires; Red = +15,
Yellow = +DT, Green = -DT, and GND = Black.
7. Plug the screw terminal onto the four pins located on the Power Center board.
8. Reinstall the cover and secure with the cover screw.
9. Proceed to “Connecting to the IntelliTouch Load Center,” on page 22.
Conduit knockout
Screw terminal
IntelliChlor Power Center (cover removed)
Screw terminal
pin-outs
1DNGKLB
2TD-NRG
3TD+LEY
4V51DER