GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 31
MAINTENANCE
Periodic Check and MaintenanceTable 7.
FIGURE PART CHECK ITEM SOLUTION
Lamp
L1 Lamp (Base) Lamp base loose? Screw in securely. •
L2 Connector Cable disconnected or loose? Connect securely. •
L3 Lamp Holder Lamp holder loose? Replace. #
L4 Pipe Frame Pipe Frame skewed Replace. &
L5 Lamp Defective lamp? Replace. •
Balloon
B1 Balloon (Envelope) Defective or dirty? Replace. •
B2 Zipper Broken? Replace. •
B3 Fan Motor (Blower) Not working properly? Repair or replace. $
B4 Buckle Broken? Replace. $
B5 T-handle bolt (balloon) Broken? Replace. •
Pentapod
P1 Pentapod Damaged or Not Working Properly? Replace. #
P2 Mast Damaged or Not Working Properly? Replace. #
P3 Latch Damaged? Replace. •
P4 Stopper Damaged? Replace. •
Electric
E1 Power cable Defective or worn cable? Replace. •
E2 Plug Damaged? Replace. #
Offset Pole
S1 Clamp Damaged? Replace. •
S2 Straight Pole Damaged or Skewed? Replace. $
S3 Offset Pole Damaged or Skewed? Replace. $
S4 Knob Loose? Tighten Securely. •
• — Check daily # — Every 20 hours $ — Every 100 hours & — Every 500 hours