Multiquip DCA-300SSK Portable Generator User Manual


 
PAGE 38 — DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/27/06)
Figure 50. Voltage Adjust Control Knob
Figure 51. Ammeter (No Load)
14. The ammeter (Figure 51) will indicate zero amps with no
load applied. When a load is applied, the ammeter will
indicate the amount of current that the load is drawing
from the generator.
13. The generator's AC-voltmeter (Figure 49) will display the
generator’s output in VOLTS. If the voltage is not within
the specified tolerance, use the voltage adjustment
control knob (Figure 50) to increase or decrease the
desired voltage.
Figure 49. Voltmeter
Figure 45. Pre-Heat Button/ Lamp
9. Place the
engine throttle control
in the “LOW” position
(Figure 46).
Figure 48. Frequency Meter (Hz)
Figure 47 Engine Ignition Switch
10. Turn the ignition key to the “START” position (Figure 47)
and listen for the engine to begin cranking. After the
engine starts release the ignition key.
Figure 46. Engine Throttle Control
11. Once the engine has started, let it run for 3-5 minutes,
then turn the throttle handle control (Figure 46) to the
HIGH” position.
7. When starting the generator in COLD weather conditions,
turn the
ignition key
to the “PREHEAT
” position (Figure 44).
Figure 44. Ignition Switch (Pre-Heat)
12. The generator's frequency meter (Figure 48) should be
displaying the 60 cycle output frequency in HERTZ.
8. Press and hold the engine preheat button (Figure 45)
until the preheat lamp is lit (ON).
6. Set the
battery ON/OFF switch
(Figure 43) to the “ON
position.
Figure 43. Battery ON/OFF Switch
DCA-300SSK SERIES — GENERATOR START-UP PROCEDURE (MANUAL)
Pre-Heat
Lamp
Pre-Heat
Button