FX2N-5A Special function block Contents.
x
7.2.12 BFM 21 Writes I/O characteristics (offset/gain Scaling function setting)
(READ/WRITE) ................................................................................................. 7-21
7.2.13 BFM 22 Convenient functions setting (READ/WRITE)...................................... 7-22
7.2.14 BFM 23 Set parameter for direct control between the input channel and output
channel (READ/WRITE).................................................................................... 7-23
7.2.15 BFM 24 Reserved ............................................................................................. 7-24
7.2.16 BFM 25 Filter-level selection register (READ/WRITE) ...................................... 7-25
7.2.17 BFM 26 Upper/lower limit value alarm status (READ only)............................... 7-28
7.2.18 BFM 27 A/D data sudden change detection status (READ only)...................... 7-30
7.2.19 BFM 28 Scale over status (READ/WRITE) ....................................................... 7-32
7.2.20 BFM 29 Error status .......................................................................................... 7-34
7.2.21 BFM 30 Model ID code (READ only)................................................................. 7-37
7.2.22 BFM 31 to BFM 40 reserved ............................................................................. 7-37
7.2.23 BFM 41 to BFM 44 Analog input Offset data (READ/WRITE)........................... 7-37
7.2.24 BFM 45 Analog output Offset data (READ/WRITE) .......................................... 7-37
7.2.25 BFM 51 to BFM 54 Analog Input Gain data (READ/WRITE) ............................ 7-38
7.2.26 BFM 55 Analog output Gain data (READ/WRITE) ............................................ 7-40
7.2.27 BFM 71 to BFM 74 Lower limit, alarm set value (READ/WRITE)...................... 7-41
7.2.28 BFM 81 to BFM 84 Upper limit, alarm set value (READ/WRITE)...................... 7-41
7.2.29 BFM 91 to BFM 94 Sudden change detection set value (READ/WRITE) ......... 7-43
7.2.30 BFM 99: Clears upper/lower limit value error and sudden change detection error
(READ/WRITE) ................................................................................................. 7-44
7.2.31 BFM 101 to BFM 108 Peak value (minimum value) (READ only)..................... 7-45
7.2.32 BFM 111 to BFM 118 Peak value (maximum value) (READ only).................... 7-45
7.2.33 BFM 109: Peak value reset flag (minimum value) (READ/WRITE)................... 7-46
7.2.34 BFM 119: Peak value reset flag (maximum value) (READ/WRITE).................. 7-46
7.2.35 BFM 200 to BFM 249 Scaling function (READ/WRITE).................................... 7-47