Lincoln Electric IM511-D Portable Generator User Manual


 
- 7 -
GENERAL DESCRIPTION
The Ranger
9, is a twin cylinder gasoline engine
driven multi-process arc welder and AC power
generator. It is built in a heavy gauge steel case for
durability on the job site.
RECOMMENDED PROCESSES AND
EQUIPMENT
The Ranger 9 can be used for AC/DC Stick welding
(CC), DC Semiautomatic wire feed welding (CV),
AC/DC Tig welding (CC), and also offers a 9,000 Watt
AC 115/230 Volt, 60 Hertz power generator.
For AC/DC Stick welding, the range is 40-250 Amps.
There is a 100% duty cycle on all settings. The
Output selector covers six ranges with remote output
control for fine current adjustment. For use with a
broad range of AC and DC electrodes including
Fleetweld
®
5P.
For DC Semi-automatic wire feed welding, three
constant voltage wire feed welding settings are
available giving a range of 40-250 Amps at 100% duty
cycle. Excellent performance will be obtained with a
broad range of Innershield
®
and Outershield
®
electrodes (FCAW). Excellent arc characteristics are
available with MIG (GMAW). An output contactor is
provided for optimum semiautomatic welding.
AC and DC Tig welding can be done at all constant
current output settings.
The auxiliary power is provided by a 9,000 Watt, AC
115/230 Volt, 60 Hertz generator. It will operate AC
power tools. It will also power a 1.5 HP motor (if
started under no load). It is capable of lighting ninety
100 Watt incandescent bulbs, and can also be used
for standby emergency power.
The Ranger 9 CSA machine (K1420-2) has four 15
amp circuit breakers for 115V auxiliary receptacles
and two 50 amp circuit breakers for 230V receptacles.
This machine is CSA approved.
SPECIFICATIONS
AC STICK / TIG (CC) OUTPUT
OUTPUT VOLTS AC
80
70
60
50
40
30
20
10
0
0 50 100 150 200 250 300
350
OUTPUT AMPS
B
B
A
A
250 OUTPUT RANGE
45 OUTPUT RANGE
DC STICK / TIG (CC) OUTPUT
OUTPUT VOLTS DC
80
70
60
50
40
30
20
10
0
0 50 100 150
200 250 300 350 400 450
OUTPUT AMPS
A
A
B
B
250 OUTPUT RANGE
45 OUTPUT RANGE
DC WIRE FEED (CV) OUTPUT
OUTPUT VOLTS DC
OUTPUT AMPS
050
100 150
200
250 300
350 400
LOW
MED
HIGH
55
50
45
40
35
30
25
20
15
10
5
0