Lincoln Electric IM511-D Portable Generator User Manual


 
– 33 –
12-16-93
M17094
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
SPARE
82
81
42
41
31
32
2
4
21
GND
75
76
77
31
32
2
4
21
GND
N.C.
K867 UNIVERSAL
ADAPTER PLUG
N.D.
N.D. SPLICE LEADS AND INSULATE.
TO WORK
ELECTRODE
TO WORK
CAUTION :
A
B
C
14 PIN
AMPHENOL
K196
INPUT CABLE
LN-8
WIRE
FEEDER
ELECTRODE CABLE
TO WIRE FEED UNIT
N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
RANGER 9 / K867 / LN-8 CONNECTION DIAGRAM
"REMOTELY CONTROLLED " POSITION.
PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION. PLACE WELDING TERMINALS SWITCH TO
N.E. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.
WARNING
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.
12-16-93
M17100
ELECTRODE CABLE
TO WORK
ELECTRODE
14 PIN
AMPHENOL
TO WORK
TO WIRE FEED UNIT
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
THE ENGINE WELDER OPERATING MANUAL.
N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE
APPLICATIONS. SEE OPERATING MANUAL.
K592 CONTROL CABLE
N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.
N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION.
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
RANGER 9 / LN-742 CONNECTION DIAGRAM
TO LN-742 INPUT
CABLE PLUG
PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.
N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.
WARNING
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.