Service as Required
RG41165,000008B –19–27JUL06–1/2
Replacing Radial Seal Air Cleaner Filter
Element
RG11321A –UN–08SEP00
Dust Cup/Cover
RG11322A –UN–08SEP00
Primary Filter Element
RG11327A –UN–08SEP00
Secondary Filter Element
A—Dust Cap/Cover
B—Primary Filter Element
C—Secondary Filter Element
IMPORTANT: ALWAYS REPLACE primary air cleaner
element when air restriction indicator
shows a vacuum of 625 mm (25 in.)
H
2
O, is torn, or visibly dirty.
NOTE: This procedure applies to John Deere 2-stage
radial seal air cleaner kits. Refer to manufacturers’
instructions for servicing air cleaners not supplied
by John Deere.
1. Unlatch and remove dust cup/cover (A) of air cleaner.
2. Move end of filter (B) back and forth gently to break
seal.
3. Pull filter (B) off outlet tube and out of housing.
4. Thoroughly clean all dirt from inside housing and from
outlet bore.
IMPORTANT: Remove secondary (safety) element (C)
ONLY for replacement. DO NOT attempt
to clean, wash, or reuse secondary
element. Replacement of secondary
element is usually necessary ONLY
when primary element has a hole in it.
5. To replace secondary element (C), pull filter element
out gently. Immediately replace secondary element
with new element to prevent dust from entering air
intake system.
6. Install new primary filter element. Apply pressure by
hand at outer rim of filter.
IMPORTANT: Do NOT use latches on cover to force
filter into air cleaner. Using cover to
force filter will damage cleaner housing.
7. Close housing with dust unloader valve aimed down
and latch latches.
40-8
080706
PN=181