Jacuzzi Comfort Plus Bath Series Hot Tub User Manual


 
ENGLISH
Note: This is a professional grade product. A knowledge of construction techniques, plumbing and electri-
cal installation according to codes are required for proper installation and user satisfaction. We recommend
that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath
©
products. Our warranty
does not cover improper installation related problems.
PRECAUTIONS
Do not operate the whirlpool system unless the bath is filled with water to at least 1" (25 mm) above the highest
jet.
Never drop or insert any object into any opening.
Do not use oil-based bath additives in your whirlpool bath.
When cleaning your bath, do not use abrasive substances which will damage the bath's surface.
To prevent discoloration of the acrylic finish, do not fill the bath with water in excess of 140° F (60° C)
The whirlpool system should be purged at least twice a month. For your convenience, we have developed a
plumbing system cleaner (Systems Clean™) specifically for whirlpool baths. For availability call 1-800-288-4002.
Use this unit only for its intended purpose as described in this manual. Do not use attachments not recom-
mended by the manufacturer.
This unit must be connected only to a supply circuit that is protected by a ground fault circuit interrupter (GFCI).
Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push
the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI
fails to operate in this manner, there is a ground current flowing, indicating a possibility of an electric shock. Do
not use this unit. Disconnect the unit and have the problem corrected by a qualified electrician before using.
A pressure wire connector is provided on the exterior of the motor to permit connection of an No. 8 AWG (8.4
mm) solid copper bonding conductor between this unit and all other electric equipment and exposed metal in the
vicinity, as needed to comply with local requirements.
This unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber.
For built-in and drop-in units, install to permit access for servicing.