Hunter Fan ICC-800PL Irrigation System User Manual


 
34
SPECIFICATIONS .....................................................................................................................
Operating Specifications
Station Run Time: 1 minute to 2 hours (in 1-minute increments) on
programs A, B, and C. Up to 12 hours on program D. The longer run
time on program D is primarily to accommodate drip irrigation
applications.
Start Times: 8 per day, per program, for up to 32 daily starts.
Watering Schedule: 7-day calendar, interval watering up to a 31-day
interval or true odd or even day programming, made possible by the
365-day clock/calendar.
Electrical Specifications
Transformer Input: 120VAC, 60Hz (230VAC, 50/60 Hz
International Use)
Transformer Output: 25 VAC, 1.5 amp
Station Output: 24VAC, .56 amps per station
Maximum Output: 24VAC, 1.4 amps (includes Master Valve Circuit)
Battery Backup: 9-volt alkaline battery (not included) used only for
time keeping during power outages, the nonvolatile memory
maintains program information
Dimensions
Plastic Cabinet Metal Cabinet Metal Pedestal
Height: 11" (28 cm) Height: 15
3
/4" (40 cm) Height: 30" (76 cm)
Width: 12" (30.5 cm) Width: 11
3
/8" (29 cm) Width:11
3
/8" (29 cm)
Depth: 3
3
/4" (9.5 cm) Depth: 4
1
/2" (11.4 cm) Depth: 4" (10 cm)
Default Settings
All stations are set to zero run time. This controller has a nonvolatile
memory that retains all entered program data even during power
outages, without need for a battery.