Hunter Fan ICC-800PL Irrigation System User Manual


 
14
CONNECTING A PUMP START RELAY ................................................................................
Common Wire
Master Valve Wire
Power Module
PSR Series
Pump Start Relay
To Pump
15' Minimum (4.5 m)
NOTE: Complete this section only if you have a
pump and pump start relay installed. A pump start
relay is an electronic device that uses a signal
current from the irrigation controller to activate a
pump to provide water to your system.
The controller should be mounted at least 15 feet (4.5 m) away from
both the pump start relay and the pump. When a pump is to be operated
by the controller, a pump start relay must be used. Hunter offers a full
range a pump start relays for most applications.
1. Route a wire pair from the pump relay into the controller housing.
2. Connect a common wire to the terminal slot C (Common) and the
remaining wire from the pump relay to the P/MV screw slot.
Relay holding current draw must not exceed .28 amps.
Do not
connect the controller directly to the pump – damage to
controller will result.