Honeywell 6067 Portable Generator User Manual


 
10
GENERATOR MAINTENANCE
SCHEDULE
Follow the recommended service schedule; to order replacement
parts call 1-855-436-4636.
Each
Use
Every 100
Hours
Every 6
Months
Each
Year
Fuel Level X
Oil Level X
Check Air Filter X
*Change Engine Oil X
**Clean Air Filter X
Check Spark Plug X
Check Muffler X
Replace Spark Plug X
Replace Fuel Filter X
* Perform initial oil change after the first five (5) hours of operation
** Clean the air filter more often if operating in dusty or sandy
conditions. Replace as necessary.
CLEANING THE GENERATOR
1. Use a damp cloth to wipe exterior surfaces clean.
2. A soft, bristle brush may be used to loosen caked on dirt, oil,
etc.
3. A vacuum cleaner may be used to pick up loose dirt and
debris.
4. Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and openings
on the generator. These openings must be kept clean and
unobstructed.
5. Inspect the vent hoses on the left side of the generator. Make
sure the hoses protrude through the slots below the door and
that the ends are open and free of debris.
ENGINE MAINTENANCE
NOTE:
Only work on a generator that has cooled completely.
Inspect the oil level and air filter condition each time you are going
to use the generator. To check the air filter and oil level the left side
service cover must be removed; use a screwdriver to loosen the
screw securing the cover and remove.
The air filter is located behind a cover for the air box (Figure 10).
Push the tab on the bottom of the air box upwards to release the
cover. To service the air cleaner:
1. Remove the air cleaner. Tap the element to shake loose any
large particles.
2. Wash the element in soapy water. Squeeze the filter dry in
clean cloth (DO NOT TWIST).
3. Soak the filter element in clean engine oil. Squeeze the excess
oil from the filter, leaving a light coating.
4. Clean air cleaner housing and cover before re-installing the
filter element.
5. To order a new air filter, you will need part number 0H63620134.
Figure 10 - Air Filter
AIR
FILTER
FILTER
HOUSING
COVER
LEFT SIDE
SERVICE COVER
SCREW
LEFT SIDE
SERVICE
COVER
CHANGING THE ENGINE OIL
Hot oil may cause burns. Allow engine
to cool entirely before draining oil. Avoid
prolonged or repeated skin exposure with
used oil. Thoroughly wash exposed areas
with soap.
Change the engine oil after the first five (5) hours of operation.
Change the engine oil every 100 hours thereafter. To change the
engine oil:
Change the oil only when the fuel tank is low
or nearly empty. Tipping the generator with a
full fuel tank may cause fuel leakage.
1. Place the generator over a drain pan and remove the drain
plug. Tip the generator on its side to drain the used oil from
the crankcase.
NOTE:
To make draining the oil easier, a 6” length of vinyl (PVC) hose
with an inside diameter of 1.25” (32mm) may be placed over
the drain lip.
2. Tip the generator upright once the oil has finished draining.
Replace the engine oil with the proper grade called out in
Section “ADDING ENGINE OIL”, then replace the drain plug.
Maintenance