Hearth and Home Technologies BODBAY Patio Heater User Manual


 
BODEGA BAY WOOD INSERT
Page 4
August 20, 2008
R
435-1320B
DIMENSIONS
TOP VIEW
SIDE VIEW
FRONT VIEW
SERIAL NUMBER LABEL LOCATION:
ON BEADED CHAIN, LEFT SIDE
BEHIND OUTER SKIN
Hearth Extension
A
B
C
D
F
E
Insert
SideWall
Maximum Mantel Depth - 10" (254mm)
Fascia or Trim
Mantel
Thermal Protection USA & Canada
USA CANADA
A Sidewall to Stove 15" (381mm) 15" (381mm)
B Mantel to Stove 26" (660mm) 23" (584mm)
C Top Trim to Stove 20" (508mm) 20" (508mm)
D Side Trim to Stove 6" (152mm) 6" (152mm)
E Hearth Extension from Glass 16" (406mm) 18" (457mm)
F
Hearth Extension from Side of Insert
8" (203mm) 8" (203mm)
Thermal protection must be 1/2 Inch (12.7mm) minimum
thickness ('k" value = 0.84) or equivalent material*
*Zero Clearance Installations USA Only
In Canada a full length six inches (152mm) S635 ue liner
required as per ULC S628.
NOTE: When installling into a masonry replace, the re-
place must be built to UBC Chapter 37 standards. Do not
remove brick or mortar from masonry replace to accomo-
date insert. The permanent metal warning plate provided
must be attached to the back of the replace stating the re-
place may have been altered to accomodate the insert and
must be returned to original condition for use as a conven-
tional replace.
CLEARANCES TO COMBUSTIBLES
United States and Canada
*See Alternative Floor Protection Worksheet on page 6.
30-3/16"
(767mm)
11-3/4"
(298mm)
24-1/16"
(611mm)
C
L
8-3/8"
(213mm)
21-9/16"
(548mm)
20-13/16"
(529mm)
11-5/16"
(287mm)
16-1/4"
(413mm)
A
B
44-5/8” (1133mm) 30-1/2” (775mm)
50-1/2” (1283mm) 34” (867mm)
Panel Size
A
B
Small
Large