7. IMPORTANT TIP: If the humidity is 90 to 100%, the Water Trap (17) will not be
able to trap all of the moisture in a 3/4 full Tank (1). It is recommended to reduce
the amount of media, load more frequently, and empty the Water Trap more
often. This will reduce the possibility of clogging the bottom of the Tank or the
line. (See Figure D.)
SKU 95014 For technical questions, please call 1-800-444-3353 PAGE 10
8. Depending on the size (diameter) of the media, install the proper size Ceramic
Nozzle (37C) onto the Blast Gun. To do so, unscrew and remove the Nozzle Cap
Nut (39C). Position the Nozzle Gasket (36C) against the Adapter (35C).
Position the proper Ceramic Nozzle (2.0mm, 2.5mm, or 3.0mm) against the
Nozzle Gasket. Then screw the Nozzle Cap Nut back onto the Adapter to secure
the Nozzle Gasket and Ceramic Nozzle in place. (See Figure E.)
WATER TRAP
(17)
FUNNEL
(29)
PRESSURE GAUGE
(15)
TANK
FILLER CAP
(12)
TANK
(1)
AIR SUPPLY VALVE
(18)
FIGURE D
FIGURE E
CERAMIC NOZZLE
(37C)
NOZZLE GASKET
(36C)
NOZZLE CAP NUT
(39C)
ADAPTER
(35C)
CONTROL LEVER (42C)