Generac Portable Products Power Transfer System
2
NOTE: The maximum load allowed through each
Load Manager switch is 7200 Watts: 30 Amps at
240 Volts or 60 Amps at 120 Volts.
Per National Electric Code, connection of a
generator to any electrical circuit normally
powered by an electric utility must be by means
of approved transfer switch equipment so as to
isolate the electrical circuit from the utility
distribution system when the generator is
operating. Failure to isolate the electrical circuits
by such means may result in injury or death to
utility power workers due to backfeed of
electrical energy.
CAUTION: Each Load Manager switch is for
indoor use only. The connection box is a NEMA
type 3R, intended for outdoor use.
NEMA stands for National Electrical Manufacturers Association.
GENERATOR
COMPATIBILITY
Only use a generator that is
factory-equipped with a NEMA
Type 14-50R receptacle.
NEVER use a generator equipped
with a 3-prong 240 Volt receptacle
because damage may occur in
connected appliances.
CARTON CONTENTS
Items in the shipping carton include:
Two Load Manager Switches
Connecting Box
Connecting Cord Set
50 Amp Connecting Plug
Attention Decal
If any of the above parts are missing or damaged, call
the Generac helpline at 18002701408.
UNPACKING
Remove the Power Transfer System components from
the shipping carton. Each Load Manager switch is
completely prewired and ready for installation. Inspect
the switches and attached wires and flexible conduit
for any shipping damage.
The connection box is supplied ready to be wired.
Inspect the box, the connection cord set, and the
connecting plug for any damage.
The installer will select and attach the connecting cord
plug, as described in the Installation Procedure,
step 22.
Items Not Shipped with Power Transfer System:
The following items, required for system installation,
are not included and must be provided by the installer:
1. Tools required for installation
2. Anchors and screws to mount the power transfer
system components and conduit.
3. Junction box(s), conduit, fittings, wire nuts, and
insulated copper wire for connecting the Load
Manager switches to the outside connection box.
SPECIFICATIONS
Model Number.......................................................1403
Maximum Circuits......................................................12
Maximum Load/Circuit from Generator ...........15 Amps
Maximum Load/Circuit from Load Center .......20 Amps
Maximum Watts per Load Manager...................7200
Connecting Cord Length .........................................8 ft.