Elation Professional Landscape Lighting Landscape Lighting User Manual


 
Design LED Par Zoom MH™
©Elation Professional 29 Design LED Par Zoom MH™
ADJU
- This function is used to calibrate the various internal motors in the event the
internal homing mechanism become slightly out of adjustment. This function is protected
with a password to prevent unauthorized personal from tampering with the fixture. To
enter the calibration menu follow the steps below:
1. Access the main menu.
2. Tap the UP or DOWN buttons until “ADJU” is displayed, then press ENTER.
3. Tap the UP or DOWN buttons until “CODE” is displayed, then press ENTER.
4. The display will show “CXXX”, were as XXX represents the calibration password.
The calibration password is “C050.” Use the UP or DOWN buttons to enter the
proper password.
5. Once the proper password is entered the display will read “CHXX”, were as “XX”
represents the fixture channel number, in the case of the DLED PAR ZOOM
MH™ 1 ~ 16.
6. Select the desired channel to be calibrated by pressing the UP or DOWN
buttons and then ENTER to confirm.
7. The display will then read “xxxx”, were “xxxx” stands for the calibrate values.
8. Adjust the desired calibration value between –128 and 127 by pressing the UP
and DOWN. As you scroll up and down through the calibration values you will
notice slight changes in the wheel or motor you are attempting to calibrate.
9. Once you reach your desired calibration press ENTER to confirm and lock in
your calibration.
14. EDIT MENU
- This menu item allows you to write a program into the fixture’s internal memory
(EEPROM) via the control panel or via an external DMX controller.
STEP (S-01 - S-48) - These are the steps slots that you write your programs into. There
are at total of 48 steps.
STXX (SC01 – SC48) - These are the scenes that are stored in your program. There are a
total of 48 scenes. C-01 - C-11 (Channel 1 - Channel 11) – Represents the total fixture
channels for each scene that can be edited.