TROUBLE SHOOTING GUIDE
No heat or heat too low
Probable Cause #1...................Dirty Filter.
Action.........................................Remove filter cartridge and clean.
Probable Cause #2...................Breaker at house off.
Action.........................................Reset breaker at house. Breaker can appear to be on
and one pole can be off. Turn breaker OFF then ON
twice.
Probable Cause #3...................Pump not primed.
Action.........................................Refer to the section of this manual on pump priming.
Probable Cause #4...................Improper line voltage.
Action.........................................Have a Licensed Electrician check the line voltage.
Spa Lights won't come on
Probable Cause #1...................Light bulb burned out.
Action.........................................Replace bulb (non-warranty).
Probable Cause #2...................Dirty connection.
Action.........................................Check to see if there is anything covering the
connection on the housing that holds the light bulb.
Pump will not prime
Probable Cause #1...................No water in pump.
Action.........................................Make sure water level in spa is correct.
Probable Cause #2...................Closed gate valves or blocked lines.
Action.........................................Open all gate valves. Check suction for blockage.
Probable Cause #3...................Pump surges, jets lose and gain power, loose union
or drain plug.
Action.........................................Check union on front or nose of pump to ensure
tightness. Check drain plugs to ensure tightness.
Jet(s) won't come on
Probable Cause #1...................Pump not primed.
Action.........................................Refer to the section of this manual on pump priming.
Probable Cause #2...................Gates valves closed.
Action.........................................Check to see if gate valves are in the correct position.
Check to see that pump is plugged in.
Probable Cause #3...................Water Diverter Valve not adjusted correctly.
Action.........................................Turn Water Diverter Valve until desired water flow is
obtained.
Probably Cause #4...................Individual jet is closed.
Action.........................................Turn the outer jet housing clockwise to turn jet on.
Low water flow
Probable Cause #1...................Dirty Filter.
Action.........................................Remove filter cartridge and clean.
Probable Cause #2...................Closed gate valves or blocked lines.
Action.........................................Open all gate valves.
Probable Cause #3...................Low voltage or incorrect voltage.
Action.........................................Have a Licensed Electrician check the line voltage.