Priming Pump For Electric Packs
The Power pack system is located under the skirting. The equipment can be
serviced by simply removing the door. The door is located on the side of the
spa where three panels are located, usually on the side of the spa with the
lounger, or the side where the topside control panel is located.
It is important to make sure that all of the air is out of the pump(s) before
operating. To do this follow procedures below:
Turn off power at the breaker
Make sure the gate valves are open
Fill the spa with water going thru the filter
Turn the power on at the breaker
Start the pump on low speed and water should start circulating within
one to two minutes. If water does not start circulating, turn pump from
low to high until prime is picked up.
If pump still does not prime, please see “Trouble Shooting Guide” located
in the back of this manua
l.
GENERAL PRE-OPERATION INSTRUCTIONS
WARNING!
Set thermostat, located on top side control panel, to desired temperature and continue
heating until desired temperature has been reached.Depending on equipment, this will
normally take 8 to 10 hours.
1. Ozonator (Optional)
2. LED Controller (Optional
3. Auxiliary Pump (Optional)
4. Power Supply (Optional)
5. Gate Valve
6. Flow Thru Heater
7. Equipment Pack
8. Dual Speed High Performance Pump
1
1
2
3
4
5
6
7
8
2
4
3
5
6
7
8
WARNING: Do not run spa with gate valve (s) closed or run pump
with no water circulating in spa for long periods. This could
damage the spa equipment.
Note: Equipment style and location will vary by model