Page 15
11.50
5.80
TOP VIEW
+ HV ADJUST
- HV ADJUST
DB-15 PINOUT
2 GROUND
3 +5VDC @ 50mA OUTPUT
6 GATE (TTL into 50 Ohms)
7 +24VDC RETURN (GROUND)
9 JUMPER TO PIN 10 FOR NON-INVERTING
10 GATE / OUTPUT POLARITY SELECT
11 JUMPER TO PIN 10 FOR INVERTING
12 GATE RETURN (GROUND)
14 POWER SUPPLY ENABLE/DISABLE (TTL HIGH = ENABLED)
15 +24-28VDC @ 600mA MAX
- PULSE OUT
- 950V MAX
+ PULSE OUT
+ 950V MAX
ELECTRONIC INSTRUMENT
FOR USE ONLY BY QUALIFIED PERSONNEL. DO NOT REMOVE COVER DURING
OPERATION. THERE ARE NO USER-SERVICABLE PARTS INSIDE.
CAUTION, RISK OF
ELECTRIC SHOCK
+/- 950V DUAL OUTPUT PULSER MODULE
DEI
PVM-4210
2.15
3.65
2.90
4.30
5.00
1.00
1.00
10.50
8-32 PEM nut for mounting
puposes far side. 4 places
4.80
PVM-4210 Mechanical Dimensions And Mounting Hole/Connector Locations
All Dimensions Are In Inches
Not To Scale