Cub Cadet Z-Force S 48 Lawn Mower User Manual


 
Service
7
25
WARNING! 

parking brake lever, turn the ignition key to the

Battery Removal
WARNING! 
accessories contain lead and lead compounds. Wash
hands after handling.
The battery is located beneath the seat box frame. To remove the
battery:


Remove the hex cap screw and sems nut securing the black 2.
negative battery lead to the negative battery post (marked

Remove the hex cap screw and sems nut securing the red 
positive battery lead to the positive battery post (marked

Carefully lift the battery out of the tractor.4.
Install the battery by repeating the above steps in the 5.
reverse order.
WARNING! Always connect the positive lead to the
battery before connecting the negative lead. This
will prevent sparking or possible injury from an
electrical short caused by contacting the tractor
body with tools being used to connect the cables.
Charging the Battery
Test and, if necessary, recharge the battery after the tractor has
been stored for a period of time.




Servicing Electrical System

damage caused by excessive amperage. Always use the same
capacity fuse for replacement. If the electrical system does not
function, check for a blown fuse.
If you have a recurring problem with blown fuses, have the

Dealer.
Relays and Switches
There are several safety switches in the electrical system. If a
function of the safety interlock system described earlier is not
functioning properly, have the electrical system checked by your

Voltmeter
Reading
State of
Charge
Charging
Time
  Full Charge
  
  
  
Figure 7-1
Figure 7-2