Cal Spas Portable Spas Hot Tub User Manual


 
2009 Portable Spa Owner’s Manual Page 13
LTR20091001, Rev. A
Operating Your Spa
Diagnostic Messages
Message Meaning
-- Spa temperature is unknown. After pump has been running for 2 minutes temperature will be
displayed.
HH Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! One sensor has detected
118˚F (48˚C) at the heater. Remove the spa cover and allow spa to cool below 107˚F (42˚C). Press
any button on the topside display to reset spa. If spa will not reset after spa has cooled, turn off
power for approximately 30 seconds and then turn power back on. If display message is repeated
then shut the power off to the spa and call your dealer or service organization.
OH Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! If the spa has reached 110˚F
(43˚C), remove the spa cover to cool the water. At 107˚F (42˚C), the spa should reset itself. If the
spa does not reset, then shut the power off to the spa, wait 30 seconds and restore power to spa.
If display message is repeated then shut the power off to the spa and call your dealer or service
organization.
IC A possible ice condition exists within the spa. No action is required, the pump will automatically
activate.
SA or Sb Spa is shut down. Spa has detected that one of the sensors is not operating properly. One of these
may display briey during overheat then disappear when overheat situation has been resolved. Call
your dealer or service organization if message does not go away.
Sn Sensor (Spa is shut down). The high limit or water temperature sensors are not working correctly.
Call your dealer or service organization.
HL A difference in readings between temperature sensors has been detected indicating a possible
water ow problem. Make sure spa is lled to proper level and that pumps are primed (water is
owing). Also check to make sure lter cartridges are clean. If message does not reset, call your
dealer or service organization.
Light
Press the Light button to turn on the light. Press it once
again to turn the light off. All optional lighting such as
the control panel light and cabinet perimeter lighting is
controlled by the Light button and will turn on and off
with the spa light.
Option
Press the Option button to turn on the pump 2 on. Press
it once again to turn off the pump 2 off.
Automatic Time outs
These features will automatically turn themselves off
during periods of continuous use:
Low speed pump After 4 hours
High speed pumps After 15 minutes
Optional circulation pump After 15 minutes
Optional turbo After 15 minutes
Spa light After 15 minutes
Setting Filtration Cycles
Your spa is programmed to lter twice a day. The rst
cycle will begin 6 minutes after the spa is turned on and the
second cycle 12 hours later. The factory has programmed
the cycle to last for 2 hours but this can be switched to
4, 6, or 8 hours depending on your requirements. To set
ltration time, turn off the power to the spa at the time
of day you would like one of the ltration cycles to begin
then turn back on after 30 seconds. When power has
been restored, press the “Temp” button then the “Jets”
button. Press “Temp” button again to change the ltering
cycle duration. When desired duration is selected press
the “Jets” button to exit.
At the beginning of each ltering cycle the Turbo system
will run for approximately 30 seconds. The low speed
pump will run for the duration of the ltering cycle and if
an Ozone system is installed it will be activated. During
ltering, “FC” will appear on the main display.