Operating Your Spa
www.calspas.com
12
Operating Your Spa
5100DV, 6200DV, and 6300DV Electronic Control Operation
These instructions will describe features and options that your particular spa may not be equipped with.
Used for single pump systems
Used for single pump
systems
Used for two and three pump
systems
When rst powered up, your spa will perform a self-
diagnostic check and go into priming mode. When
the control panel displays PR, do the following:
Press the JETS 1 button to turn on the pump and 1.
let it run for 10 seconds. The pump should be
running in low speed.
Press the JETS 1 buttons again and let the pump 2.
run in high speed for 10 seconds.
Press the JETS 1 button again to turn off the 3.
pump. The pump should be left in the off position
for 10 to 15 seconds.
Repeat steps 1 through 3 until water is owing 4.
through all the jets and all air is removed from
the plumbing.
When the spa has nished priming, the heater will
be activated and the water temperature will be
maintained in standard mode. The spa will heat to
100°F (37.5°C) at start up until the set temperature
is changed as described below.
Initial Start up