2010 Portable Spa
LTR20101000, Rev. C
Operating Your Spa
www.calspas.com
13
Standard, Economy and Sleep Heating
Modes
Your new spa is equipped with a heating feature that
gives you complete control of the heating system.
When the spa is powered up, it will automatically start
in standard heating mode.
St• will light briey on the main display. In this
mode, the heating system will automatically
maintain the set spa temperature. In the economy-
heating mode, the heating system will only activate
during ltration times.
Ec• will display solid if temperature is not current
and will alternate with spa temperature if measured
temperature is current.
Economy mode will heat the water to the set •
temperature while Sleep mode, indicated by a
SL on the main display, will also only activate
the heater during the ltering cycles but will
only heat the water to within 20°F (10°C) of the
set temperature. Like Economy mode, SL will
display solid when temperature is not current and
will alternate with actual temperature when it is
current.
NOTE: Displayed temperature will only be current after
the pump has been running for at least two minutes.
Switching Modes
Press • Temp button followed by the Light
button.
Press the same sequence to switch to the next •
mode.
Jets
Press the Jets button:
Once to activate low speed pump.•
Twice to activate high speed.•
Three times to turn pump off.•
Light
Press the Light button to turn on the light. Press it
once again to turn the light off. All optional lighting
such as the control panel light and cabinet perimeter
lighting is controlled by the Light button and will turn
on and off with the spa light.
Option
Press the Option button to turn on the pump 2. Press
it once again to turn off the pump 2 (6200 control
only).
6300 Control - Pump 2 and Pump 3
Sequence
Press • Option button once to activate high speed
pump 2.
Press • Option button twice to activate high speed
pump 3 and high speed pump 2.
Press three times to activate pump 3 high speed •
only.
Press four times to turn pumps off.•
“Green Pack” Operation
Spas with the “Green Pack” option require approximately
20% less power to operate. Once the spa is properly
installed, it does not require any special operation.
This is for your information only.
When JETS 1 is pressed, the heater will operate at
220V. When JETS 2 or OPTION is pressed (depending
on which control panel you have), the heater will
automatically switch to operate at 110V.
With the “Green Pack”, your spa will never use more
than 30 amps while in operation.
Automatic Time outs
These features will automatically turn themselves off
during periods of continuous use:
Low speed pump After 4 hours•
High speed pumps After 15 minutes•
Optional circulation pump After 15 minutes•
Optional turbo After 15 minutes•
Spa light After 4 hours•
Setting Filtration Cycles
Your spa is programmed to lter twice a day. The rst
cycle will begin 6 minutes after the spa is turned on
and the second cycle 12 hours later. The factory has
programmed the cycle to last for 2 hours but this can
be switched to 4, 6, or 8 hours depending on your
requirements. To set ltration time, turn off the power
to the spa at the time of day you would like one of
the ltration cycles to begin then turn back on after
30 seconds. When power has been restored, press
the Temp button then the Jets button. Press Temp
button again to change the ltering cycle duration.
When desired duration is selected press the Jets
button to exit.
At the beginning of each ltering cycle the Turbo system
will run for approximately 30 seconds. The low speed
pump will run for the duration of the ltering cycle
and if an Ozone system is installed it will be activated.
During ltering, FC will appear on the main display.