Bolens BL410 Cultivator User Manual


 
15
CAUSE ACTION
On/Off Stop Control in the STOP position Turn the On/Off Stop Control to START
Empty fuel tank Fill fuel tank
Primer bulb wasn't pressed enough Press primer bulb fully and slowly 10 times
Engine flooded Use starting procedure with choke control in RUN
Old or improperly mixed fuel Drain fuel tank / Add fresh fuel mixture
Fouled spark plug Replace or clean the spark plug
Plugged spark arrestor Clean or replace spark arrestor
ENGINE WILL NOT START
CAUSE ACTION
Air Filter is Plugged Replace or clean the air filter
Old or improperly mixed fuel Drain fuel tank / Add fresh fuel mixture
Improper carburetor adjustment Adjust according to the Carburetor Adjustments section
ENGINE WILL NOT IDLE
CAUSE ACTION
Old or improperly mixed fuel Drain fuel tank / Add fresh fuel mixture
Improper carburetor adjustment Take to an authorized service dealer for a carburetor adjustment
Cultivator tines bound with dirt or grass Stop the unit, switch the On/Off Stop Control to STOP,
clean and remove any debris binding the tine
Dirty air filter Clean or replace the air filter
Plugged spark arrestor Clean or replace spark arrestor
ENGINE WILL NOT ACCELERATE
CAUSE ACTION
Old or improperly mixed fuel Drain fuel tank / Add fresh fuel mixture
Improper carburetor adjustment Take to an authorized service dealer for a carburetor adjustment
Fouled spark plug Replace or clean the spark plug
Plugged spark arrestor Clean or replace spark arrestor
ENGINE LACKS POWER OR STALLS WHEN UNDER LOAD
TROUBLESHOOTING