Electrical Installation Requirements
IMPORTANT: Electrical ratings are subject to
change. Refer to serial decal for electrical ratings
information specific to your machine.
Electrical connections are made at the rear of the
machine. The machine must be connected to the
proper electrical supply shown on the identification
plate attached to the rear of the machine, using copper
conductors only.
IMPORTANT: Alliance Laundry Systems
warranty does not cover components that fail as a
result of improper input voltage.
Make sure the correct transformer jumper (208 Volt or
240 Volt) is in place. Refer to the “optional” Electrical
Service Connection label located on the back of the
machine near the electrical service input for machine
electrical requirements. Refer to Figure 26.
Figure 26
Machines equipped with an AC inverter drive require
a clean power supply, free from voltage spikes and
surges. Use voltage monitor to check incoming power.
The customer’s local power company may provide
such a monitor.
Hazardous Voltage. Will cause shock,
burn or death. Allow machine power to
remain off for three minutes prior to
working in and around AC inverter drive.
W735
DANGER
Dangerous voltages are present inside
the machine. Only qualified personnel
should attempt adjustments and
troubleshooting. Disconnect power from
the machine before removing any cover
and guards, and before attempting any
service procedures.
W736
WARNING
Hazardous Voltage. Can cause shock,
burn or death. Verify that a ground wire
from a proven earth ground is connected
to the lug near the input power block on
this machine.
W360
WARNING
CHM2287N
1 Electrical Service Connection Label
1