![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/36/5364c56c-183f-4c00-a51a-c49c69e543e7/5364c56c-183f-4c00-a51a-c49c69e543e7-bg4e.png)
69
Palameter List
PARAMETERS
4
Power failure stop function
261 Power failure stop selection 0, 1 1 0 172
262
Subtracted frequency at
deceleration start
0 to 20Hz 0.01Hz 3Hz 172
263 Subtraction starting frequency
0 to 120Hz, 9999
0.01Hz 60Hz 172
264 Power-failure deceleration time 1
0 to 3600/0 to 360 s
0.1 s/0.01 s 5 s 172
265 Power-failure deceleration time 2
0 to 3600/0 to 360 s,
9999
0.1 s/0.01 s 9999 172
266
Power-failure deceleration time
switchover frequency
0 to 400Hz
0.01Hz 60Hz 172
Selection
function
270
Stop-on-contact/load torque high-
speed frequency control selection
0, 1, 2, 3
1 0 173
High-speed
frequency
contro
271
High-speed setting maximum
current
0 to 200%
0.1% 50% 174
272 Mid-speed setting minimum current
0 to 200%
0.1% 100% 174
273 Current averaging range
0 to 400Hz, 9999
0.01Hz 9999 174
274 Current averaging filter constant
1 to 4000
1 16 174
Stop on
contact
275
Stop-on-contact exciting current
low-speed multiplying factor
0 to 1000%, 9999
1% 9999 (Note 5) 178
276
Stop-on-contact PWM carrier
frequency
0 to 15, 9999
1 9999 (Note 5) 178
Brake sequence functions
278 Brake opening frequency (Note 3) 0 to 30Hz 0.01Hz 3Hz 181
279 Brake opening current (Note 3) 0 to 200% 0.1% 130% 181
280
Brake opening current detection
time (Note 3)
0 to 2 s 0.1 s 0.3 s 181
281
Brake operation time at start (Note
3)
0 to 5 s 0.1 s 0.3 s 181
282 Brake operation frequency (Note 3) 0 to 30Hz 0.01Hz 6Hz 181
283
Brake operation time at stop (Note
3)
0 to 5 s 0.1 s 0.3 s 181
284
Deceleration detection function
selection (Note 3)
0, 1 1 0 181
285 Overspeed detection frequency 0 to 30Hz, 9999 0.01Hz 9999 181
286 Droop gain 0 to 100% 0.1% 0% 185
287 Droop filter constant 0.00 to 1.00 s 0.01s 0.3s 185
Additional
function
342
E
2
PROM write selection
0, 1 1 0 130
Capacitor life
503 Capacitor life timer 186
504
Capacitor life alarm output setting
time
0 to 9998 (9999) 1 (100h) 876 (87600h) 186
Restart
611 Restart acceleraation time 0 to 3600s 9999 0.1s 5.0s 96
Calibration functions
900 FM terminal calibration 187
901 AM terminal calibration 187
902 Frequency setting voltage bias 0 to 10V 0 to 60Hz 0.01Hz 0 0Hz 189
903 Frequency setting voltage gain 0 to 10V 1 to 400Hz 0.01Hz 5V 60Hz 189
904 Frequency setting current bias 0 to 20mA 0 to 60Hz 0.01Hz 4mA 0Hz 189
905 Frequency setting current gain 0 to 20mA 1 to 400Hz 0.01Hz 20mA 60Hz 189
Additional
function
990 PU buzzer control 0, 1 1 1 194
991 PU contrast adjustment
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Factory Setting
Refer
To
Page:
Customer
setting