Palameter List
PARAMETERS
Advanced magnetic flux vectorcontrol
80 Motor capacity 0.4 to 55kW, 9999 0.01kW 9999 116
81 Number of motor poles 2, 4, 6, 12, 14, 16, 9999 1 9999 116
82 Motor excitation current (Note 4) 0 to , 9999 1 9999 117
83 Rated motor voltage 0 to 1000V 0.1V 200/400V (Note 2) 117
84 Rated motor frequency 50 to 120Hz 0.01Hz 60Hz 117
89 Speed control gain 0 to 200.0% 0.1% 100% 116
90 Motor constant (R1) (Note 4) 0 to, 9999 9999 117
91 Motor constant (R2) (Note 4) 0 to, 9999 9999 117
92 Motor constant (L1) (Note 4) 0 to, 9999 9999 117
93 Motor constant (L2) (Note 4) 0 to, 9999 9999 117
94 Motor constant (X) (Note 4) 0 to, 9999 9999 117
95 Online auto tuning selection 0, 1 1 0 127
96 Auto tuning setting/status 0, 1, 101 1 0 117
5-point flexible V/F
characteristics
100 V/F1 (first frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 129
101
V/F1 (first frequency voltage) (Note
1)
0 to 1000V 0.1V 0 129
102 V/F2 (second frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 129
103
V/F2 (second frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 129
104 V/F3 (third frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 129
105
V/F3 (third frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 129
106 V/F4 (fourth frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 129
5-point flexible V/F
characteristics
107
V/F4 (fourth frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 129
108 V/F5 (fifth frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 129
109
V/F5 (fifth frequency voltage)
(Note 1)
0 to 1000V 0.1V 0 129
Third functions
110 Third acceleration/deceleration time
0 to 3600 s/0 to 360 s,
9999
0.1 s/0.01 s 9999 77
111 Third deceleration time
0 to 3600 s/0 to 360 s,
9999
0.1 s/0.01 s 9999 77
112 Third torque boost (Note 1) 0 to 30.0%, 9999 0.1% 9999 73
113 Third V/F (base frequency) (Note 1) 0 to 400Hz, 9999 0.01Hz 9999 75
114
Third stall prevention operation
current
0 to 200% 0.1% 150% 91
115
Third stall prevention operation
frequency
0 to 400Hz 0.01Hz 0 91
116 Third output frequency detection 0 to 400Hz, 9999 0.01Hz 9999 90
Communication functions
117 Communication station number 0 to 31 1 0 130
118 Communication speed 48, 96, 192 1 192 130
119 Stop bit length / data length
0, 1 (data length 8)
10, 11 (data length 7)
1 1 130
120 Parity check presence/absence 0, 1, 2 1 2 130
121 Number of communication retries 0 to 10, 9999 1 1 130
122 Communication check time interval 0, 0.1 to 999.8 s, 9999 0.1 s 0 130
123 Waiting time setting 0 to 150ms, 9999 1ms 9999 130
124 CRLF presence/absence selection 0,1,2 1 1 130
PID control
128 PID action selection 10, 11, 20, 21  10 141
129 PID proportional band 0.1 to 1000%, 9999 0.1% 100% 141
130 PID integral time 0.1 to 3600 s, 9999 0.1 s 1 s 141
131 Upper limit 0 to 100%, 9999 0.1% 9999 141
132 Lower limit 0 to 100%, 9999 0.1% 9999 141
133
PID action set point for PU
operation
0 to 100% 0.01% 0% 141
134 PID differential time 0.01 to 10.00 s, 9999 0.01 s 9999 141
Func-
tion
Parameter
Number
Name Setting Range
Minimum
Setting
Increments
Factory Setting
Refer
To
Page:
Customer