5. BASE SPECIFICATIONS PARAMETERS
II - 60
# Items Details Setting range (unit)
1227 aux11
(bit0)
Select PLC
signal or spindle
feedrate
attained
Set up this option when disabling the cutting start
interlock by spindle feedrate attained.
0: Cutting start interlock by PLC signal
1: Cutting start interlock by spindle feedrate
attained
0/1
aux11
(bit1)
Select H or D
code
Set up this option to validate the data that is set up
on the tool life management screen when issuing
the H99 or D99 command.
0: The H and D codes validate the data that is set
up on the management setup screen.
1: Validates the data that is set up on the
management setup screen when issuing the
H99 or D99 command.
0/1
aux11
(bit2)
Measures
against tool
setter chattering
Select a condition where a relieving operation
completes after measurement with tools.
0: Sensor signals has stopped for 500 ms or
longer.
1: 100 ยตs or longer has passed after sensor
signals stopped.
0/1
aux11
(bit4)
Program
address check
Specify whether to simply check the program
address when the machining program is executed.
0: Don't check the program address.
1: Check the program address.
0/1
aux11
(bit5)
Spindle rotation
speed clamp
Specify whether to clamp the rotation in constant
surface speed mode when the spindle rotation
speed clamp command is issued.
0: Clamp the rotation regardless of the constant
surface speed mode.
1: Clamp the rotation only in constant surface
speed mode.
0/1