A SERVICE OF

logo

49
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Operations
ALARM REC DURATION
The recording time during alarm recording can be set.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
>>
ALARM REC DURATION 5S
MOTION DET REC ALARM
ARCHIVE OVERWRITE OFF
ARCHIVE MEDIA AUTO EJECT OFF
Setting ( default : 5S )
2S, 5S, 10S, 15S, 30S, 45S, 1M, 2M,
5M, 10M, 20M, 30M, 60M, MANUAL
MANUAL : Alarm recording is continued until the
grounding of the ALARM IN terminals is removed.
1. Press the SET UP button
}
<SETTINGS>
}
Select ALARM
REC DURATION in the <RECORD SETTINGS> screen.
Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.
MOTION DET REC
Select if alarm recording or normal recording is to be started
when motion is detected.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
ALARM REC DURATION 5S
>>
MOTION DET REC ALARM
ARCHIVE OVERWRITE OFF
ARCHIVE MEDIA AUTO EJECT OFF
Setting ( default : ALARM )
ALARM : Alarm recording is started when the mo-
tion is detected.
NORMAL : Normal recording is started when the
motion is detected.
Recording is done with the recording interval and
the quality set by A-PPS and A-GRADE, inde-
pendent of whether ALARM or NORMAL has
been selected.
1. Press the SET UP button
}
<SETTINGS>
}
Select
MOTION DET REC in the <RECORD SETTINGS> screen,
and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
ARCHIVE OVERWRITE
When backing-up data with an ARCHIVE device, the unit
can be set to start overwriting from the beginning.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
ALARM REC DURATION 5S
MOIOTN DET REC ALARM
>>
ARCHIVE OVERWRITE OFF
ARCHIVE MEDIA AUTO EJECT OFF
This setting appears when ARCHIVECOPY is
selected on ID4ID5 of the <INITIALIZATION>
screen.
ARCHIVE OVERWRITE starts back up after all
data on the ARCHIVE device is deleted.
This setting does not function during Timer re-
cording. Select OVER or OVER-E in the <TIMER
PROGRAM> screen to perform archive in Timer
recording mode.
Setting ( default : OFF )
OFF : Do not overwrite data when start archive.
ON : Overwrite data when start archive.
1. Press the SET UP button
}
<SETTINGS>
}
Select
ARCHIVE OVERWRITE in the <RECORD SETTINGS>
screen, and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.
ARCHIVE MEDIA AUTO EJECT
Automatic media ejection after completion of archive can
be set.
<RECORD SETTINGS>
ALARM SETTING
RECORD SETTING
ALARM REC DURATION 5S
MOITON DET REC ALARM
ARCHIVE OVERWRITE OFF
>>
ARCHIVE MEDIA AUTO EJECT OFF
When the DVR archive media is full, the unit
stops archiving and ejects the ARCHIVE media au-
tomatically.
This setting appears when ARCHIVE COPY
is selected on ID4ID5 of the <INITIALIZATION>
screen.
This setting does not function during Timer re-
cording. Select OVER-E or CONT-E in the
<TIMER PROGRAM> screen to perform ARCHIVE
MEDIA AUTO EJECT in Timer recording mode.
Setting ( default : OFF )
OFF : Do not automatically eject media after com-
pletion of archive.
ON : Automatically eject media after completion
of archive.
1. Press the SET UP button
}
<SETTINGS>
}
Select
ARCHIVE MEDIA AUTO EJECT in the <RECORD
SETTINGS> screen, and display the desired setting.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button to exit.