Basic Operations
■ Basic manual recording
Information on normal recording is provided bolow. Before
starting recording, recording settings must be checked.
After checking the settings of “HDD REPEAT REC MAIN”,
“HDD REPEAT REC SUB” in the <HDD SETTINGS>
screen ( see page 53), the REC mode settings are
made.
Settings here are for normal recording only. For
timer recording, settings must be made on the
<TIMER PROGRAM SETTINGS> screen (
see
page 50).
♦ Setting the recording interval and recording
picture quality for normal recording
To perform normal recording, “PPS” and “GRADE” must
be set for each camera.
Setting of “PPS” ( default : “1.875P” )
“3.75P”, “
1.875P”, “1.25P”, “0.938P”, “0.75P”,
“0.625P”, “0.375P”, “0.25P”, “0.125P”, “0.063P”,
“0.031P”, “0.016P”, “- - - - - -”
“- - - - - -” : Indicates that the camera is not active
and recording cannot be performed with this cam-
era.
Available recording intervals will vary according
to the number of cameras operating or ALARM RE-
CORDING settings (
see page 47). Interval dis-
plays will be according to the chart.
Setting of “GRADE” ( default : “STD” )
“SUPER”, “HIGH”, “
STD”(STANDARD), “BASIC”,
“LONG”
Example : Set “PPS” of camera number “
1
” to “0.25P”
and “GRADE” to “HIGH” for normal recording.
1. Press the SET UP button to display the <SETTINGS> screen.
2. Turn the JOG dial to move the cursor to “RECORD
SETTINGS” and turn the SHUTTLE ring clockwise.
• The <RECORD SETTINGS> screen appears.
<RECORD SETTINGS>
>>
ALARM SETTING
RECORD SETTING
ALARM REC DURATION 5S
MOTION DET REC ALARM
ARCHIVE OVERWRITE OFF
ARCHIVE MEDIA AUTO EJECT OFF
3. Turn the JOG dial to move the cursor to “RECORD
SETTING” and then turn the SHUTTLE ring clockwise.
• The <RECORD SETTING> screen appears.
<RECORD SETTING>
>>
ALARM
NO PPS GRADE A-PPS A-GRADE
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
NEXT PAGE SHUTTLE<<:BACK
<RECORD SETTING> 1/2
Camera selection during alarm recording
9
7
4
5
6
1
2
3
8
<RECORD SETTING> ALARM
NO PPS GRADE A-PPS A-GRADE
>>
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
PRE ALARM REC ( S ) S
SHUTTLE<<:BACK
<ESTD REC> D H M
<RECORD SETTING> 2/2
10
11
13
14
15
16
12
CAUTION : For <ESTD REC>, see
“Continuous recording time table”, pages 92, 93.
About <ESTD REC >
• The estimated recordable time is displayed as <ESTD REC>
depending on the “PPS” and “GRADE” settings. (The time
will not change when changing the alarm recording settings.)
The RECORD SETTING consists of 2 pages. The
next page appears when select “NEXT PAGE” (turn
the SHUTTLE ring clockwise) as shown below .
4. Turn the JOG dial to move the cursor to “
1
”, and then turn
the SHUTTLE ring clockwise.
• The “PPS” setting reverses in color.
<RECORD SETTING> ALARM
NO PPS GRADE A-PPS A-GRADE
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
NEXT PAGE SHUTTLE<<:BACK
9
7
4
5
6
1
2
3
8
5. Turn the SHUTTLE ring clockwise again.
• The background of the “PPS” setting turns red and flashes.
<RECORD SETTING> ALARM
NO PPS GRADE A-PPS A-GRADE
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
1.875P STD 1.875P STD
NEXT PAGE SHUTTLE<<:BACK
9
7
4
5
6
1
2
3
8