1 SAS/SATA RAID front retention bracket
2 SAS/SATA RAID riser card
3 ServeRAID-BR10i adapter
4 Alignment post
5 Plastic tab
8. Route the signal cables from the drive backplane over the blue adapter
retention bracket as shown in the following illustration.
1 Connector for drive bays 0-3 signal cable
2 Connector for drive bays 4-5 signal cable
3 SAS/SATA RAID riser-card
4 ServeRAID-BR10i adapter
9. Take the signal cable that is attached to the drive backplane for drive bays 4
and 5 and connect it to the RAID controller connector that is closest to the
power supply cage. Connect the other signal cable so that is attached to the
drive backplane for drive bays 0 through 3 and connect it to the other connector
on the controller. The following illustration show how to route the signal cables.
Note:
When you restart the server, you will be prompted to import the existing
RAID configuration to the new ServeRAID controller.
Chapter 5. Installing optional devices and replacing customer replaceable units 67