Topside Controller Instructions cont...
Temp/Set (80°F - 104°F / 26°C - 40°C)/ Freeze
Protection
Temp/Set (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set to 100°F/37°C. The Last measures
temperature is constantly displayed on the LCD.
NOTE: The last measured spa temperature displayed is current
only when the pump has been running for at least 1 minute.
To display the set temperature, press the “Cool” or “Warm” pad
once.
To change the set temperature, press the pad a second time before
the LCD stops ashing. Each press of the “Cool” or “Warm” pad will
continue to either lower of raise the set temperature respectively.
After three seconds, the LCD will stop ashing and display the cur-
rent spa temperature.
Freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C within
the heater, the pump will automatically activate to provide freeze
protection. The equipment stays on until 4 minutes after the sen-
sors detect that the spa temperature has risen to 45°F/7.2°C or
higher. In cold climates, an additional freeze sensor may be added
to protect against freeze conditions that may not be sensed by the
standard sensors. Aux freeze sensor protection acts similiarly ex-
cept with the temperature thresholds determined by the switch and
without a 4-minute delay in turnoff. See your dealer for details.