Zenith C-30HDG Chainsaw User Manual


 
PAGE 36 — MAYCO C-30HDG PUMP — OPERATION AND PARTS MANUAL — REV. #6 (04/02/12)
Starting
1. Hold the throttle control switch fully to the RIGHT to set the
engine speed to IDLE (Figure 20).
Figure 20. Throttle Control Switch
2. Place
the pumping control switch (Figure 21) in the OFF
position.
Figure 21. Pumping Control Switch (OFF)
During
pumping operations
, the engine speed
cannot be reduced below 1300 RPM's.
CAUTION - General Saftey
DO NOT attempt to operate this concrete pump
until the Safety, General Information and
Inspection sections have been read and
understood.
C-30HDG PUMP — INSPECTION/STARTUP
Checking Engine Coolant Level
1. Remove the radiator cap, and check the cooling water level
inside the radiator (Figure 18).
2. Maintain water/coolant level at top of radiator coils. Make sure
radiator overflow bottle is filled to the proper level.
Figure 18. Radiator Coolant
Figure 19. V-Belt Deflection
V-Belt Deflection
1. Visually inspect the V-belt for cracks, fraying, wear or oiliness.
2. Make sure V-belt does not the bottom the pulley groove.
3. Check the V-belt tension (Figure 19) by pushing midway through
the two pulleys. The V-belt deflection should be between .300 to
.472 inches (8 to 12 mm).
NEVER remove the radiator cap when the
engine is HOT! Allow the engine to cool
before remove the cap.
WARNING - Burn Hazards
3. Check the radiator and hoses for any signs of leakage.
4. If cooling water is dirty, flush the cooling system.
5. When using antifreeze, mix the antifreeze coolant with water.
Observe the instructions on the antifreeze container. Usually
a 50/50 mixture is a good choice.
6. When replacing the radiator cap, be sure to fit it securely back
onto the radiator. If replaced loosely or incorrectly, the cooling
water will quickly evaporate, causing the engine to overheat.)
This built in feature protects the clutch from disengaging (slipping)
during operation.